← EFTA00304364Dataset 9EFTA00304410 →

EFTA00304368

Dataset 9 · 42 pages · 2.8 MB · 11,602 words

People (2) #

Extracted Text #

Articles in PresS. J Neurophysiol (July 13, 2011). doi:10.1152/0.00104.2011
Neural decoding of treadmill walking from non-invasive,
2    electroencephalographic (EEG) signals
3
4
5    Alessandro Presacco', Ronald Goodmans, Larry Forrester" and Jose Luis Contreras-Vidal 23
6
7
8   University of Maryland, College Park:
9   'Neural Engineering and Smart Prosthetics Research Laboratory, Department of Kinesiology,
10   School of Public Health
II   2Fischell Department of Bioengineering
12   3Graduate Program in Neuroscience and Cognitive Science;
13
14   University of Maryland, Baltimore:
15   'Department of Physical Therapy & Rehabilitation Science, University of Maryland School of
16   Medicine
17   'Veteran Affairs Medical Center, Baltimore
18
19
20   Author Contributions: JLCV conceived the research; JLCV designed the experiment with
21   assistance from LF; AP, LF and RG performed the research at the VAMC; AP and JLCV
22   designed the decoders, and analyzed the data at UMCP; AP and JLCV wrote the paper; and LF
23   and RG edited the manuscript.
Correspondence to:
Alessandro Presacco or Jose L. Contreras-Vidal
School of Public Health, Department of Kinesiology
SPH Building, University of Maryland, College Park
College Park, MD 20742
Tel: ([Phone Redacted], Email: ([Email Redacted]; [Email Redacted]
24
Copyright © 2011 by the American Physiological Society.
EFTA00304368
25
26
27
28   Abstract
29   Chronic recordings from ensembles of cortical neurons in primary motor and somatosensory
30   areas in rhesus macaques provide accurate information about bipedal locomotion (Fitzsimmons et
31   al. 2009). Here we show that the linear and angular kinematics of the ankle, knee and hip joints
32   during both normal and precision (attentive) human treadmill walking can be inferred from
33   noninvasive scalp electroencephalography (EEG) with decoding accuracies comparable to those
34   from neural decoders based on multiple single-unit activity (SUAs) recorded in nonhuman
35   primates. Six healthy adults were recorded. Participants were asked to walk on a treadmill at their
36   self-selected comfortable speed while receiving visual feedback of their lower limbs (i.e.,
37   precision walking), to repeatedly avoid stepping on a strip drawn on the treadmill belt. Angular
38   kinematics of the left and right hip, knee and ankle joints and EEG were recorded, and neural
39   decoders were designed and optimized using cross-validation procedures. Of note, these decoders
40   were also used to accurately infer gait trajectories in a normal walking task that did not require
41   subjects to control and monitor their foot placement. Our results indicate a high involvement of a
42   fronto-posterior cortical network in the control of both precision and normal walking and suggest
43   that EEG signals can be used to study in real-time the cortical dynamics of walking and to
44   develop brain-machine interfaces aimed at restoring human gait function.
45
46
47
Key Words: BCI; BMI; EEG; neural decoding; treadmill; walking
48
49
50
51
2
EFTA00304369
52
53
54   Introduction
55   Little is known about the organization, neural network mechanisms and computations underlying
56   the control of walking in humans (Choi and Bastian 2007). Although central pattern generators
57   for locomotion are important in the control of walking, supra-spinal networks, including the
58   brainstem, cerebellum and cortex, must be critical as demonstrated by the changing motor and
59   cognitive (i.e., spatial attention) demands imposed by bipedal walking in unknown or cluttered
60   dynamic environments (Choi and Bastian 2007; Grillner et al. 2008; Nielsen 2003; Rossignol et
61   al. 2007). Neuroimaging studies show that rhythmic foot or leg movements recruit primary motor
62   cortex (Christensen et al. 2001; Dobkin et al. 2004; Heuninckx et al. 2005; Heuninckx et al. 2008;
63   Luft et al. 2002; Sahyoun et al. 2004), whereas electrophysiological investigations demonstrate
64   electrocortical potentials related to lower limb movements (Wieser et al. 2010), as well as a
65   greater involvement of human cortex during steady-speed locomotion than previously thought
66   (Gwin et al. 2010a, 2010b). In this regard, studies using functional near-infrared spectroscopy
67   (fN1RS) show involvement of frontal, premotor and supplementary motor areas during walking
68   (Harada et al. 2009; Miyai et al. 2001; Suzuki et al. 2008; Suzuki et al. 2004). That primary
69   sensorimotor cortices carry information about bipedal locomotion has been directly proven by the
70   work of Nicolelis and colleagues (Fitzsimmons et al. 2009), who demonstrated that chronic
71   recordings from ensembles of cortical neurons in primary motor (MI) and primary somatosensory
72   (S1) cortices can be used to predict the kinematics of bipedal walking in rhesus macaques.
73   However, neural decoding of bipedal locomotion in humans has not yet been demonstrated. Here
74   we compare the predictive power of neural decoders based on human scalp (noninvasive) EEG
75   signals during treadmill walking with that reported from multiple single unit activity (SUA) in the
76   rhesus monkey performing bipedal treadmill walking (Fitzsimmons et al. 2009). We demonstrate
77   the feasibility of using scalp EEG to reconstruct the detailed kinematics of human walking, and
78   the potential of the proposed approach as a new tool for inferring the cortical contributions to
79   walking.
3
EFTA00304370
80
81
82
83
84    Materials and Methods
85
86    Experimental setup and procedure. Six healthy adults, aged 18-45 (3 male, 3 female) with no
87    history of neurological disease or lower limb pathology and free of injury participated in the
88    study after giving informed consent. The study was conducted with approved protocols from the
89    Institutional Review Boards at the University of Maryland College Park, the University of
90    Maryland Baltimore, and the Baltimore VA Research and Development Committee.
91    Participants were first asked to walk on a treadmill, to establish their comfortable speed during a
92    5-minute familiarization period that preceded the beginning of the recordings. Next, a 2-minute
93    rest period (baseline) while standing on the treadmill was followed by 5-minutes of precision
94    walking, when subjects were instructed to walk on the treadmill at their comfortable speed while
95    receiving real time visual feedback (30 frames/sec) of their lower limbs through a video monitor
96    in front of them. Subjects were told to avoid stepping on the white stripe (2 inches wide) glued
97    diagonally on the treadmill's belt by using the monitor's video to keep track of foot placement
98    relative to the white stripe. This increased the attentional demands during treadmill walking
99    (Yogev-Seligman et al. 2008), a condition that can be considered to mimic walking in a novel
100   environment or under novel conditions (e.g., after brain injury). Thus, the precision walking
101   paradigm puts us a step closer to the actual application where patients have impaired gait function
102   and therefore would need to rely purely or significantly on effortful attentive conscious control of
103   gait. In an ancillary task, a subset of the participants whose decoders showed the best and worst
104   decoding performance in the precision walking task were also tested under normal walking
105   conditions that did not require precise positioning of the feet nor monitoring of foot placement
106   through a computer monitor (subjects were instructed to direct their gaze straight ahead).
107
108   Limb movement and EEG recordings. The three-dimensional (3D) joint kinematics of the hip,
109   knee and ankle joints were recorded using an infrared optical motion capture system (Optotrak,
110   Northern Digital, Ontario, Canada @ 100 Hz) with foot switch data (Koningsberg
4
EFTA00304371
III   Instrumentation, Pasadena, CA, @ 100 Hz). Precision manufactured 5 cm diameter disks
112   (Innovative Sports Training, Chicago, IL), each embedded with three infrared diodes that formed
113   an equilateral triangle (--3 cm sides), were affixed with adhesive and secured with foam wrap at
114   the second sacral vertebra (S-2) and on the thigh, shank, and foot segments of each lower limb. A
115   segmental model of the lower limbs was then determined by digitizing joint centers for the hip,
116   knee and ankle joints of each limb. Gait kinematics were derived from the model using motion
117   analysis software (Motion Monitor, Innovative Sports Training, Chicago, IL) and exported as
118   ascii files containing time histories of the X, Y & Z positions, joint angular positions and joint
119   angular velocities for the hip, knee and ankle joints of the right leg. Whole scalp 60-channel EEG
120   (Neuroscan Synamps2 RT, Compumedics USA, Charlotte, NC, USA) and electro-ocular activity
121   were recorded (sampling rate of 500 Hz; band-pass filtered from 0.1 to 100 Hz; right ear lobe
122   (A2) was used as a reference) and time-locked with the movement kinematics using the
123   footswitch signals.
124
125   Power spectral density analysis. The power spectral density (PSD) for the kinematic data and for
126   each channel of the EEG recorded during rest and during the walking task for the 6 subjects was
127   computed using the adaptive Thompson's multitaper method as implemented in Matlab's pnam
128   function. The time-bandwidth product for the discrete prolate spheroidal sequences used was 4
129   and the frequency resolution 0.1 Hz. The confidence interval was set to 95% and was estimated
130   using a chi-squared approach. In order to account for the variability of the kinematics, and for
131   purposes of cross-validation of the decoders (see the Model performance metrics subsection),
132   during the walking task, the data for each gait parameter (x, y,z,0,0/dt) were divided into 5
133   segments (I minute each one) and the PSD was calculated for each of these 5 segments
134   independently. The segments were then averaged across all the parameters and all the subjects
135   leading to a grand average of the PSD. Frequencies ≤ 3 Hz accounted for > 90% of the total PSD
136   for the kinematics. The same segmentation was applied to each channel of the EEG recorded
137   during rest and walking conditions. The PSD of each segment was averaged across channels and
138   then averaged across subjects leading to a grand average. The grand averages for the kinematics
5
EFTA00304372
139   and the EEG were then smoothed with local regression using weighted linear least squares and a
140   2nd degree polynomial model as implemented in the Matlab's loess function with a span
141   (percentage of the total number of data points) of 10%.
142
143   Signal preprocessing. Figure 1 shows our decoding methodology. All the data analysis, decoder
144   design and cross-validation procedures were performed off-line using custom software written in
145   MATLAB (Mathworks Inc., Natick, MA). The most frontal electrodes (FPI, FP2, FPz) were
146   removed off-line from all the subjects, as they are usually contaminated by eye-blinks. Temporal
147   electrodes were also removed, as they are most susceptible to artifacts from facial and cranial
148   muscle activity (Goncharova et al. 2003). Signals from each EEG electrode were decimated by a
149   factor of 5 (to 100 Hz), then filtered with a zero-phase, 3rd order, band-pass Butterworth filter
150   (0.1 - 2 Hz) and normalized by subtracting their mean and dividing by their standard deviation
151   (Bradberry et al. 2010). Kinematic data were filtered with a zero-phase, 3rd order, band-pass
152   Butterworth filter (0.1 — 3 Hz), as this frequency range accounted for 90% of the signal power.
153
154   Decoding method. A time-embedded (10 lags, corresponding to 100 ms in the past) linear Wiener
155   filter (Bradberry et al. 2010; Carmen et al. 2003; Fitzsimmons et al. 2009) was independently
156   designed, optimized, and cross-validated for each extracted gait parameter. The linear model was
157   given by:
158
N   L
159                                  y(t)= a +EEb aiSn(t — k)+ e(t)
st=1 k=0
160
161   where y(t) is the gait parameter measured (x,             I dt) time series representing the linear
162   and angular kinematics, and their time derivatives, for the hip, knee and ankle joints; L and
163   N are the number of lags and the number of electrodes, respectively; 5.(r — k) is the
164   standardized voltage measured at EEG electrode n at lag time k, a and b are weights
165   obtained through multiple linear regression and e(t) is the residual error. The parameters of the
6
EFTA00304373
166   model were calculated using the standard GLM functions in MATLAB under the Gaussian
167   distribution using the Matlab's linear link function.
168
169   Model peformance metrics. In order to assess and compare the predictive power of each decoder
170   (neural decoders were trained independently for each subject, and each decoded parameter), a 5-
171   fold cross validation procedure; i.e., 5 distinct sets of test data that were not used to train the
172   decoder were employed for testing purposes. That is, the data recorded during the 5 minutes of
173   the walking task were divided into 5 segments (1 minute each one). Four segments were used for
174   training, while the remaining segment was used for testing the model. This procedure was
175   repeated for all the possible combinations. The Pearson correlation coefficient ( r ) was calculated
176   between the known measured signal and the predicted decoder's output as follows:
177                                                      cov(x,i)
r(x,1)-
a zo i
178
179   where x is the actual measured parameter, 1 is the prediction of that parameter and crx and
180   a l are the standard deviations of x and 1 respectively.
181   The SNR (signal to noise ratio) was calculated according to Fitzsimmons et al. (2009).
182
Var(x))
SNR(x,i) =10 logio(
183                                                                    MSE(x)
184
185   where the variance (Var) of the actual measured parameter (signal x) was calculated by
186   subtracting out the mean of the signal, then squaring and averaging the amplitude. The noise or
187   error (1 ) was the difference between the predicted and actual measured signal. The mean squared
188   error (MSE) was calculated by squaring the difference, then averaging to get the mean squared
189   error (MSE), or the power of the noise. The ratio between Var(x) and MSE(i) was converted
190   into a decibel (dB) scale. A SNR with a value of "0" means that the signal and the noise are
191   equally present in the reconstructed kinematic parameter. A SNR < 0 (poor prediction) indicates a
192   noisy reconstruction, while a SNR > 0 (good prediction) indicates a high-quality reconstruction of
193   the signal.
7
EFTA00304374
194
195           Sensor dropping analysis. A sensor dropping analysis (SDA) was used to evaluate the
196   importance of groups of sensors of different sizes to decoding accuracy (e.g., Carmen et al.
197   2003; Fitzsimmons et al. 2009). First, decoder models were trained by using each lag of each
198   sensor (one lag at a time) with the above mentioned 5-fold cross validation procedure. In order to
199   rank the sensors, two different methods were then used based on which kinematic parameter was
200   to be decoded. For the joint angle (0) and the angular velocity (d0/ dt) the sensors were ranked
201   based on the maximum value of the correlations calculated at each lag. For the Cartesian
202   positions (x, y,z) reconstructions, the sensors were ranked according to the following sensor
203   sensitivity curve equation (Bradberry et al. 2010):
204
205                                    —
R,,                    +    + c:t ,
206                                        L+1k.o
207   where L is the number of lags, R. is the rank of sensor n and c are the best correlation
208   coefficients for each Cartesian position (x,y,z). These procedures were followed for all the 45
209   sensors used for decoding after removing the most prefrontal and temporal electrodes. The best
210   34 and 16 sensors out of the 45 sensors ranked were then used for training and testing the
211   decoders for each kinematic parameter extracted.
212
213   Decoding kinematics by regions of interest (RO1). In order to assess the contribution to the
214   decoding of each scalp area, the scalp was divided into 5 major ROIs: prefrontal (PF), central
215   (SM), posterior-occipital (PO) and right (RH) and left (LH) hemispheres. The kinematics were
216   decoded using the sensors belonging to each of these ROIs, leading to 5 different decoders for
217   each parameter for each joint and each subject.
218
219   Scalp Maps. To visualize the relative contributions of scalp regions to the reconstruction of the
220   position (x,y,z), joint angle (0) and the angular velocity (O1dt) of the hip, knee and ankle
221   joints, the squared correlation (i.e., variance) values c for each sensor at each lag were projected
EFTA00304375
222   into a time series of scalp maps (-100-0 ms in increments of 10 ms for a total of 11 scalp maps).
223   The topoplot function of EEGLAB [Delorme and Makeig 2004 (http://sccn.ucsd.edukezlab/)]
224   was used to plot the correlation values. The contribution of the reconstruction of each lag, for the
225   Cartesian data, was calculated as follows (Bradberry et al. 2010):
226
EN           Ai 2 far + C2   CI nix
%Ti =%100* " L
n=1
227
228
229
Ejjc2 -Fc2 + c2„,,
rt=1 kw()
230
231   for all i from 0 to L, where %Ti is the percentage of reconstruction contribution at time lag i.
232
233   Artifacts. To address the issue of potential mechanical artifacts introduced by motion of the EEG
234   cap wires to the recording amplifiers (due in turn to movement of the subject) the phase-locking
235   value (PLV) (Lachaux et al. 2000, 2002) was computed by using Morlet wavelets (Tallon-Baudry
236   et al. 1997). We made the assumption that if the motion of the EEG wires corrupted in some way
237   the measured EEG signals, this problem should have been observed in all the electrodes as the
238   wires were bundled in a single connector. We were particularly interested in investigating the
239   phase in the 1-2 Hz range, as these were the main frequencies used for decoding. We calculated
240   the PLV between each electrode for the walking task and the corresponding kinematics recorded
241   from the subjects. The averaged values of PLV at 1 and 2 Hz were averaged across the electrodes,
242   leading to a mean value at the two frequencies of interest, and compared with the correlation
243   values of the decoding.
244   Analysis of potential eye movement contributions to decoding. In order to assess a potential
245   contribution of the movement of the eyes to decoding, the decoding process was also carried out
246   by adding the standardized vertical electrooculogram (VEOG) activity to the optimal set of
247   electrodes used for decoding (Bradberry et al. 2011). The r-values and the regression weights
248   were calculated in this new condition. We compared the r-values with and without the VEOG
249   electrode by calculating the difference in % and divided the absolute value of the regression
250   weights of the eye-electrode by the sum of the absolute value of all the regression weights of the
251   best fold.
9
EFTA00304376
252
253   Results
254   Spectral signature of walking kinematics and associated high-density EEG. The power spectral
255   density (PSD) of the gait kinematics (black) in the 0.1 — 5 Hz range along with the 95%
256   confidence intervals (gray) are depicted in Figure 2A. The PSD shows that > 90% of the power is
257   contained in the 0.1 — 3 Hz frequency band with a peak (26.45 dB) at —1.8 Hz. The ratio between
258   upper and lower bounds of the confidence interval throughout all the frequencies was —6.6 dB.
259   Confidence intervals (95%) of the PSD of the EEG at rest (black) and during precision walking
260   (gray) are shown in Figure 2B. Notably, PSD(walking) > PSD(rest) in the delta and theta bands
261   (-0.1 - 7 Hz) and in the low beta range (13 — 18 Hz), whereas for frequencies > 18 Hz the
262   PSD(walking) < PSD(rest). Importantly, the suppression in the mu band observed during upper
263   limb movements (Pfurtscheller et al. 2006) is also present during precision walking in the 8 — 12
264   Hz range. This is clearly depicted in the plot of the ratio of PSD(walking) to PSD(rest) shown in
265   the inset. Of note, the ratio in the 0.1 — 2 Hz range used for decoding was — 1.0 dB implying that
266   walking did not alter the spectral signature in this low frequency band (i.e., low delta) — a finding
267   consistent with the data reported by Gwin et al. (2010).
268
269   Decoding accuracy. Our EEG decoding method was able to reconstruct 3D linear and angular
270   kinematics of the ankle, knee and hip joints with high accuracy. In order to quantify the level of
271   accuracy, we computed the Pearson's r and the SNR between measured and predicted Cartesian
272   positions, joint angles and angular velocities across cross-validation folds. SNR proved to be a
273   more sensitive measure compared to r, which describes the correspondence of signal waveforms,
274   but is insensitive to amplitude scaling and offsets. The average of the correlation values (r)
275   between predicted and recorded kinematics for the six subjects was 0.75 (I0.1) and the signal-to-
276   noise ratio values > 0 (4.13 I 2.03) in all but one measure (subject S6: x axis of the ankle; SNR =
277   -0.35I1.09) confirmed the good quality of the decoded signals. Overall, correlation values across
278   the subjects were slightly higher for joint angle (mean r = 0.78I0.1) and angular velocity (mean r
279   = 0.78&0.09) than for Cartesian positions (mean rx‘,..,= 0.71I0.13). Figures 3(A) and 3(B), show,
10
EFTA00304377
280   respectively, examples of the measured (black) and the reconstructed (gray) kinematics for the
281   best (S4) and worst (S5) subjects in terms of decoding accuracy. As it can be seen, even in the
282   case of the worst case we were able to decode the kinematic parameters with an accuracy r =0.67
283   t 0.09. The quality of the reconstructions of the gait trajectories in 3D space is shown in Figure 4,
284   where an example of the actual and predicted angular velocities and joint angles, and their
285   relative phasing, for the ankle, knee and hip, for subject S4 are depicted in 3D space as well.
286           Table 1 reports the mean and the standard deviation (SD) of the correlation coefficients
287   (r) and of the SNR (dB) values across cross validation folds for all subjects, the best (S4) and
288   worst (55) cases (subjects), and for intra-cortical recordings from rhesus monkey I (Fitzsimmons
289   et al. 2009), while Figure 5 shows the distribution of the correlation coefficients (r) versus SNR
290   (dB) for the 6 subjects and for the 2 rhesus monkeys reported in the Fitzimmons' experiment. All
291   the decoded accuracies resulted in mean r values > 0.5 and high SNR values (all but one > 0),
292   which were comparable with the values reported using recording spikes from rhesus monkeys
293   (Fitzsimmons et al. 2009). In order to rule out the hypothesis that the visual feedback aided
294   decoding, we report in Table 2 the r and SNR values of the best and worst subject decoded under
295   natural walking conditions (no visual feedback and no stripe to step over) from our ancillary task.
296   We used the neural decoders, previously trained using data from the precision walking task, to
297   predict the linear and angular kinematics during normal walking. The decoding accuracies
298   reported for the two conditions were comparable. The avenges of the correlation values (r)
299   between predicted and recorded kinematics for the precision and natural walking task for S4 were
300   respectively 0.8510.08 and 0.7I-0.13, while for S5 were respectively 0.67t0.09 and 0.78&0.12.
301
302   Decoding accuracy by Region ofInterest (RO1). Figure 6 depicts the mean decoding accuracy
303   across the three joints for the 5 different ROIs. For both the angular velocity and the joint angle
304   the r and SNR values were higher when all the sensors found during the decoder optimization
305   phase were used to decode. Decoders built based on a subset of electrodes comprising the right
306   (RH) or left (LH) hemispheres scalp regions showed the highest r values among the selected
307   ROIs, while the subset of electrodes spanning the central scalp ROI (SM) showed the lowest r
11
EFTA00304378
308   values. In terms of SNR, the right hemisphere, prefrontal; and posterior-occipital ROIs returned
309   the highest values, while the central scalp ROI returned the lowest values. However, statistically
310   these differences were not significant (Kruskal-Wallis test; all comparisons at p 0.05).
311
312   Topography of the correlation values of the sensors. The topography of the squared correlation
313   (i.e., variance) values of the sensors at the best lag for the best (subject S4) and worst (subject 55)
314   decoded cases is plotted in Figure 7. These scalp maps represent the individual contribution of
315   electrodes to decoding, that is, the spatial distribution of the EEG information about walking
316   contained at each electrode site. From these scalp maps, it can be inferred that neural information
317   about walking is distributed across a sparse cortical network at the macro-scale of EEG. Scalp
318   maps of sensors most relevant to decoding of the right limb suggest that scalp areas from both
319   hemispheres, somewhat lateralized to the right are involved during walking. Although there are
320   some common scalp regions relevant across all the gait parameters, these scalp regions
321   accounting for the highest variance are different across the two subjects S4 and 55. For instance,
322   C6, FZ, 135, and AF4 electrodes are recruited across gait parameters for subject S4, whereas for
323   subject S5 electrode locations at FC6, P6, and PO2 on the right hemisphere seemed to be relevant
324   for decoding walking across all the kinematic parameters. There were also other important
325   differences across subjects. For example, in subject S4 decoding of both Cartesian and angular
326   kinematics recruited anterior scalp areas (electrode locations AF3, FZ and AF4) that in some
327   cases extended to left frontal sites (F5). These scalp areas were absent in subject S5 who showed
328   the lowest decoding accuracies.
329           Of note, the scalp maps of the highest (e.g., r42 > 0.2) electrode contributions to decoding
330   the right limb kinematics were rather sparse, particularly for subject S5, who showed rather focal
331   recruitment of electrodes on the right hemisphere, compared with a more bilateral, but still sparse
332   recruitment of electrodes for subject S4. In summary, a sparse network comprised of right
333   posterior-occipital, right lateral, and bilateral anterior-frontal scalp regions appeared to contain
334   decodable gait information.
335
12
EFTA00304379
336   Minimum number ofsensors. Given that the analysis of scalp maps relevant for decoding showed
337   a sparse cortical network for walking, the number of sensors was further optimized using the
338   SDA approach. As shown in Figure 8, the average number of sensors needed to achieve the
339   reported correlations was —27-32, but on average decoding accuracy reached a phase of plateau
340   (i.e., an improvement in DA < 5%) with 14 sensors (Figure 8A). As shown, with an average of
341   27 sensors (i.e., the 'best' sensors), the mean r value across the 6 subjects was 0.75 (&0.06) (black
342   bars), while selecting the best 14 sensors led to a mean r value across the 6 subjects of 0.72
343   (&0.06) (white bars), that is, less than 5% reduction in decoding accuracy (Figure 8B).
344
345   Discussion
346   Gait kinematics can be inferred from scalp EEG signals with high accuracy. This study
347   demonstrates, for the first time, that non-invasive scalp electroencephalographic (EEG) signals
348   can be used to decode kinematic parameters extracted during walking with high accuracy. Of note
349   is the fact that even though we recorded EEG from 60 channels, which some investigators
350   consider to be high-density recordings (Tononi et al. 2010), we showed that as few as 16 sensors
351   were required for decoding with high accuracy. Encouraged by promising results achieved in
352   previous studies carried out in our laboratory (Bradberry et al. 2008, 2009a, 2009b, 2010), we
353   designed neural decoders by using time-domain EEG features extracted solely from the
354   fluctuations in the amplitude (i.e. amplitude modulation or AM) in the EEG signals in the low
355   delta frequency band (0.1 — 2 Hz).
356           Even though Onton et al. (2005) reported significant changes in the theta band (4 — 8 Hz)
357   reflecting increasing cognitive demands, we emphasize that our decoders were designed to use
358   information contained in the delta band only. Moreover, our decoders were able to predict gait
359   kinematics under two different conditions (precision walking and normal walking), which clearly
360   differ in terms of the cognitive demands and task constraints, and thus changes in cognitive
361   demands or modulations in higher frequency bands could not contribute to decoding.
362           Our decoding approach proved to be robust as it prevents over-fitting (i.e., by employing
363   separate training and testing trials) and minimize the effect of artifacts because trials with artifacts
l3
EFTA00304380
364   in the training set would contribute minimally to the learning of the optimal decoder weights, and
365   those in the test set could only reduce, not improve, the decoding accuracy (Tsuchiya et al. 2010).
366   The fact that critical information for decoding lower limb kinematics is contained in the smoothed
367   amplitude modulations (AM) in the lower half of the so-called delta band (i.e., 0.1 — 4 Hz) is
368   consistent with recent EEG, electrocorticographic (ECoG), and local field potential (LFP) upper
369   limb movement decoding studies that use the fluctuations in the amplitude of highly smoothed
370   signals for decoding (Walden et al. 2008; Lv et al. 2010; Ball et al. 2009; Acharya et al 2010;
371   Ince et al. 2010; and Zhuang et al 2010). It is also consistent with observations by Gwin et al.
372   (2010a), who showed that meaningful changes during walking or running occur at low
373   frequencies (< 10 Hz) in high-density EEG.
374           Fitzsimmons et al. (2009) were the first to prove that linear decoders could be used to
375   reconstruct locomotion, but their experiments were based on intracortical recordings (spikes) in
376   nonhuman primates. Ferris and colleagues have recently shown electrocortical activity coupled to
377   gait cycle phase during treadmill walking in humans (Gwin et al. 2010b), but their study did not
378   decode gait parameters from the EEG signals. In our experiment, 6 subjects were asked to walk at
379   their preferred speed on a treadmill while receiving visual feedback of their lower limbs (through
380   a video monitor at eye level in front of them), to repeatedly avoid stepping on a strip drawn on the
381   treadmill belt — a condition we called precision walking. Even though angular kinematics were on
382   average slightly better decoded than linear kinematics, we could not identify any parameter that
383   stood out as the best for decoding, except for the Cartesian "x" parameters which showed a lower
384   decoding performance overall. All the kinematic parameters but "x" position were decoded with
385   mean r values > 0.7 (mean r, = 0.67 (a0.16), mean r).= 0.77 (&0.1),    = 0.77 (a-0.13), rank = 0.78
386   (a0.09), r an, / = 0.78 (a0.1); and no statistical difference was found among the 5 parameters (p >
387   0.01, ANOVA). Moreover, as shown in Figure 4, the phasing relationship between ankle, knee
388   and hip angular kinematics is preserved in the reconstructed trajectories even though the three
389   joints were decoded independently from each other. Remarkably, as depicted in Figure 6, SNR
390   and r values were comparable to the ones reported by Fitzsimmons et al. (2009), a result that
391   supports the hypothesis that the EEG signals in the low delta frequency band over a large but
14
EFTA00304381
392   sparse cortical network contain decodable information that could be used to design EEG-based
393   brain-machine interface (BMI) systems for restoration of lower limb movement. It cannot be
394   overemphasized that the same decoders calibrated using data from the precision walking task
395   were able to reconstruct the gait kinematics during normal walking, which did not require
396   subjects to monitor and control foot placement and had not access to visual feedback of foot
397   placement, thus demonstrating the robustness of our methods.
398
399   Scalp map analysis. Decoder optimization and scalp maps of correlations for the right limb
400   confirmed that human walking is sub-served by a complex, distributed but sparse cortical
401   network, in which different scalp areas over anterior, right lateral and right anterior-occipital
402   scalp areas seem to equally contribute to the decoding, at least at the macro-scale of EEG. As we
403   decoded the right leg only, it still remains to be seen whether this sparse network that encoded
404   right-side lower limb kinematics would be mirrored in the case of the left leg kinematics.
405           Our best decoded case (subject S4) showed the highest gait-related information in the
406   bilateral anterior, and the lateral and posterior-occipital scalp areas in the right hemisphere. Of
407   note, our worst subject (subject S5) showed a lack of anterior-frontal recruitment for decoding the
408   right limb, which may explain the lower decoding accuracies. In fact, it is plausible that because
409   the precision walking task presumably involves both visual attention and decision making with
410   respect to deciding when or how best to avoid stepping in the white line drawn on the treadmill,
411   this lack of anterior-frontal recruitment for decoding affected the overall performance. The fact
412   that different scalp brain areas could equally contribute to the decoding is supported by the r and
413   SNR values obtained when decoding kinematic parameters using only sensors from specific ROIs.
414   In fact, even though differences in terms of r and SNR were observed between the 5 selected
415   ROIs, statistically these differences were not significant. Our observations are in agreement with
416   the findings by Gwin et al. (2010b), who used source analysis and reported electrocortical sources
417   in the anterior cingulate, posterior parietal and sensorimotor cortex associated with intra-stride
418   changes in spectral power. During the end of stance, they also observed that alpha and beta band
419   spectral power increased in or near the left/right sensorimotor and dorsal anterior cingulated
15
EFTA00304382
420   cortex. However, power increases in the left/right sensorimotor cortices were more pronounced
421   for contralateral limb push-off than for ipsilateral limb push-off. Studies carried out using fNIRS
422   also showed involvement of frontal, premotor and supplementary motor areas during walking
423   (Harada et al. 2009; Miyai et al. 2001; Suzuki et al. 2008; Suzuki et al. 2004). These results
424   support the idea that walking is represented across a plurality of cortical brain areas.
425
426   Minimum number ofsensors. An important issue in brain-machine interface design is concerned
427   with the minimum number of sensors necessary to achieve a reasonable decoding accuracy. As it
428   is well-known (Alpaydin 2004), a common occurrence in machine learning is the fact that as the
429   number of input features increases, the decoding accuracy of the predictions increases up to a
430   certain point, after which the model becomes too complicated, over-fitting might occur and as a
431   consequence of this fact performance decreases. Given this, we decided to compare the r values
432   obtained with the number of sensors found in the SDA with the best r values obtained by using up
433   to 16 sensors. Our results indicate that —14 sensors could be sufficient to decode human
434   locomotion using EEG.
435
436   Variability ofthe kinematics and its relation with decoding accuracy. Spectral analysis of the gait
437   kinematics showed that more than 90% of the power was retained in the 0.1 — 3 Hz range,
438   justifying our choice to band pass filter the kinematic data within this frequency range. The 6.6
439   dB ratio of the upper and lower confidence intervals suggested a significant variability of the
440   kinematic parameters across the 6 subjects. This variability could be due to the fact that each
441   subject chose his/her comfortable pace for the walking task, but also varied his/her gait speed
442   during the task. Consistent with upper limb movement decoding studies (Bradberry et al. 2010), a
443   negative correlation between movement variability and decoding accuracy was found when
444   decoding gait parameters for both angular velocity and joint angle decoding (Figure 9).
445   Specifically, the relationship between the decoding accuracy and gait variability, as measured by
446   the kurtosis (kurtosis = 3 implies normal distribution), for angular velocity and the joint angle
447   was estimated. Low values of the kurtosis (-3) (Figure 9) and high decoding accuracy for both
16
EFTA00304383
448   the angular velocity and the joint angle suggest that a normal distribution is responsible for an
449   increase in decoding accuracy.
450
451   Decoding accuracy was not affected nor corrupted by eye, mechanical or EMG artifacts. The
452   spectral analysis of the EEG showed interesting results. As in the case of the upper limbs
453   (Pfurtscheller et al. 2006), a desynchronization during the walking task was found in the mu band
454   (8 — 12 Hz). As reported by Gwin et al. (2010a), PSD values during walking were generally
455   higher than PSD values during rest (i.e., standing) at low frequencies (0.1 — 7 Hz) and in the
456   middle beta band (13 — 18 Hz). The ratio of PSD(walking) to PSD(rest), albeit small (e.g., — 1dB
457   in the 0.1 — 2 Hz), is consistent with those observations. Moreover, Gwin et al. (2010) reported
458   that gait-related artifacts removed from EEG signals were insubstantial when subjects walked at a
459   slow pace (0.8trils = 2.88 km/h). In our experiments, no subject walked faster than 2.4 km/h, thus
460   reducing further the likelihood of mechanical artifacts. Nevertheless, it could still be argued that
461   EEG signals measured during gross motor tasks like walking are prone to a myriad of
462   physiological, mechanical, and environmental artifacts that would prevent accurate measurement
463   and analysis of cortical dynamics during treadmill walking (Gwin et al. 2010a). However, our
464   proposed method for reconstruction of gait parameters and additional analyses of the potential
465   influence of artifactual components to gait decoding suggest otherwise.
466           First, the decoding accuracies with and without inclusion of the vertical electrooculogram
467   (VEOG) electrode were similar. For all the decoded gait parameters except for the ankle in
468   subject 2 (S2, r.v = 5.1%, r,„ = 9.6%), the addition of the VEOG electrode increased negligibly the
469   decoding accuracy by a maximum of 3.1%. The contribution of VEOG in terms of regression
470   weights was also negligible for all decoded gait parameters except for the reconstruction of limb
471   trajectories in the ankle's z-dimension for subject 2 (S2, r,= 28%). Furthermore, S2 showed the
472   lowest r -value for the ankle (r,= 0.31I-0.19), supporting the notion that eyes movements did not
473   contribute to the high r and SNR values found in this study. Results are reported in Table III. It is
474   also important to point out that in the normal walking condition, subject's gaze was instructed to
475   be maintained straight ahead. This condition is likely to be associated with significant eye
17
EFTA00304384
476   movements due to the compensation of displacements of the head during walking (and neck
477   muscle activity). Indeed, significant eye movements have been reported during standing and
478   walking (Gramann et al., 2010). However, two lines of reasoning argue against the potential
479   contributions of eye movement to decoding: First, the same decoder was used to infer limb
480   kinematics in two conditions (normal walking and precision walking) that differed in the pattern
481   of eye movements (gaze straight ahead vs. monitoring foot placement in a monitor), and second,
482   the correlation analysis showed that eye movements did not assist gait decoding.
483           Second, Goncharova et al. (2003) has shown that electromyographic (EMG) and ocular
484   artifacts do generally occur mainly at frequencies higher than 8 Hz, which is 4 times higher than
485   our frequency cutoff of 2 Hz used for reconstruction. Moreover, Goncharova et al. (2003)
486   reported that EMG activity was localized to the frontal and temporal electrodes in the specific
487   frequency band we used for decoding (delta, < 4 Hz). Therefore, in our study frontal and temporal
488   electrodes were removed from the analysis.
489           Third, correlation values were also calculated between baseline EEG signals band-pass
490   filtered at 0.1 — 2 Hz and gait kinematics (< 3 Hz) and compared with EEG signals acquired
491   during walking, which we hypothesized contained relevant information about gait parameters.
492   Indeed, our results showed that attempting to map baseline EEG signals to gait parameters
493   resulted in extremely low decoding: as a representative example, the r and SNR values for the
494   ankle joint angle for our best decoded subject (S4) were 0.05 I 0.07 and -15.27 I 33.27,
495   respectively, for the baseline EEG signals, whereas decoding accuracies were high (0.87 I 0.01
496   and 6.1 I 0.59 for r and SNR, respectively) when using EEG signals acquired during the walking
497   task, confirming that EEG signals measured during walking contained detailed cortical
498   information about gait parameters.
499          Fourth, to rule out the presence of mechanical artifacts introduced by motion of the EEG
500   cables or walking itself, we computed the phase-locking value (PLV) among sensors. The
501   rationale was that potential motion artifacts due to EEG wires or the subject's motion would
502   affect all sensors equally. To assess the phase-locking value using wavelet analysis, the
503   significance threshold value was set based on the values calculated by Lachaux et al. (2002). In
18
EFTA00304385
504   our case, since we used 6 cycles (tiro ) for the wavelets and 10 cycles (nn,) for the integration
505   window, the significance threshold was estimated to be 0.71. We applied such analysis to both the
506   baseline EEG and the walking EEG conditions. Our results suggest that mechanical artifacts did
507   not play a role in decoding. As a representative example, the mean PLVs across electrodes of our
508   best subject (S4) for the ankle joint angle kinematic during walking were 0.55 a 0.08 at 1 Hz,
509   0.53 a 0.05 at 2 Hz and 0.54 a 0.06 average across 1-2 Hz (the lower bounds for gait-cycles were
510   ≥ 1Hz). Remarkably, when the baseline EEG condition was used, the mean values across
511   electrodes were 0.37 a 0.02 (at 1 Hz), 0.49 a 0.03 (at 2 Hz) and 0.43 a 0.01 (mean of 1 and 2 Hz),
512   which were comparable to those during walking and suggesting lack of mechanical coupling due
513   to concerted wire movement.
514           Fifth, we note that our decoding accuracies were high independently of whether the
515   reconstructed parameters were linear or angular gait kinematics. It is very unlikely that a (global)
516   motion artifact would affect or influence equally both types of gait parameters. For example,
517   mechanical artifacts due to up-down motion would be expected to affect the decoding of vertical
518   trajectories of the hip, ankle and knee joints, but not the decoding of angular joint velocities as
519   they are not linearly related. Nevertheless, the motion of the center of mass (COM), which would
520   be expected to be directly related to that of any upward/downward movement of the EEG wires
521   due to the subject's mechanical motion was very small (sacrum's vertical movement, in meters:
522   SI = -0.01 a 0.015, S2 = 0.0006 a 0.007, S3 = -0.006 a 0.015, S4 = -0.005 a 0.013, S5 = -0.0095
523   a 0.016, S6 = -0.007 a 0.012). In addition to this, decoding of angular velocities (not linearly
524   related with the 3D translational movements of the cables or the sacrum) for the ankle, hip, and
525   knee resulted in high decoding accuracies that were comparable to the ones of the joint angle and
526   Cartesian positions. Furthermore, it is unlikely that the motion artifact would have been the same
527   for both walking conditions; indeed, the fact that the same decoders were used to decode gait in
528   both walking (precision & normal) conditions is a strong argument against the potential influence
529   of movement artifacts to decoding.
530           Finally, we note that the mapping of the spatial distribution of the highest contributing
531   electrodes to decoding resulted in a sparse but distributed network lateralized to the right
19
EFTA00304386
532   hemisphere with a bilateral anterior contribution suggesting specificity of the cortical
533   representation of the right limb's role in walking is contained in the EEG signal. Our scalp maps
534   allowed us to map electrode locations on the scalp surface according to the maximal amount of
535   information that they might carry about each gait parameter. Remarkably, the scalp maps were
536   different across gait parameters; that is, the amount and type of information about gait was
537   different across electrode sites. As noted above, the same network was used for decoding both
538   walking conditions.
539           Overall, these results demonstrate the feasibility of employing a noninvasive EEG-based
540   brain-machine interface (BMI) for the restoration of gait. This view is supported by fMRI studies
541   in which cortical activation was detected when subjects imagined themselves walking (Bakker et
542   al. 2007, 2008; Iseki et al. 2008) and when paraplegic patients imagined foot and leg movements
543   (Alkadhi et al. 2005; Cramer et al. 2005; Hotz-Boendermaker et al. 2008). A cortically EEG-
544   driven BMI for the restoration or rehabilitation of walking could be also used as a strategy to
545   harness or potentiate the remaining functionality and plasticity of spinal cord circuits isolated
546   from the brain (Behnnan et al. 2006; Grasso et al. 2004; Lunenburger et al. 2006), and as a new
547   tool for assessing the cortical contributions to walking in health and disease, or to study the
548   changes in these contributions during learning and adaptation.
549
550   Conclusion. We have shown the feasibility of decoding human walking under precision
551   (attentive, requiring visually-guided foot placement) and normal (subjects's gaze was straight
552   ahead) conditions by using scalp EEG with as few as 16 electrodes. The fact that these two
553   conditions were decoded using the same decoder calibrated in the more complex precision
554   walking task attests to the robustness of the decoding approach. Future studies should investigate
555   the applicability of the present findings to the development of brain-machine interfaces and the
556   suitability of the proposed approach to examine cortical plasticity during gait rehabilitation.
557
558
559
20
EFTA00304387
560
561   Acknowledgements: This research has been supported by the University of Maryland College
562   Park-University of Maryland-Baltimore Seed Grant Program to JLCV and LF. Support by the VA
563   Maryland Exercise & Robotics Center of Excellence (VA RR&D B3688R) and by the University
564   of Maryland's Department of Kinesiology Graduate Student Research Initiative Fund are gladly
565   acknowledged. We thank Dr. Richard F. Macko for his support and valuable discussions during
566   the performance of this study.
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
21
EFTA00304388
588
589   Figure Captions
590
591   Figure 1: Diagram depicting the decoding methodology. The subject was fitted with a 60 channel
592   EEG cap to record brain activity and a plurality of sensors were used to record 3D kinematics and
593   footswitch data. EEG and kinematics were synchronized, preprocessed and saved. The training,
594   testing and optimization of individual neural decoders, for each decoded gait parameter, were
595   performed off-line using cross-validation procedures.
596
597   Figure 2: A. Mean power spectral density (PSD in dB/Hz, in black) and 95% confidence
598   intervals (in gray) of the grand mean of the kinematic parameters across the six subjects. B.
599   Confidence intervals (95%) of the power spectral density (PSD in dB/Hz) of the EEG recorded
600   during rest and walking of the grand mean (not shown) across the six subjects. The black lines
601   represent the PSD at rest, while the gray lines represent the PSD during walking. The inset shows
602   the ratio PSD (walking) to PSD (rest).
603
604   Figure 3: Reconstructed right leg kinematics from EEG for the 'best' (S4, A) and 'worst' (S5, B)
605   decoded subjects. Columns represent ankle, knee and hip joints. Each row represents comparison
606   of reconstructed (gray) and actual (black) measured linear kinematic trajectories for (x, y, z), joint
607   angle and angular velocity time series at the optimal number of sensors.
608
609   Figure 4: Actual and predicted standardized 3D trajectories for angular velocity and joint angle of
610   the ankle for subject S4. Ankle, knee and hip trajectories are plotted respectively in the x, y and z-
611   axes. The letter "S" represent the starting point. A: trajectories of the predicted (black) vs. actual
612   (gray) angular velocities; B: trajectories of the predicted (black) vs. actual (gray) joint angles.
613
22
EFTA00304389
614   Figure 5: Comparison of decoding accuracy (r) vs. SNR (dB) for the current study (N=6) with the
615   nonhuman primate study (monkeys 1 and 2) of Fitzsimons et al. (2009). Stars represent monkeys,
616   while squares represent the 6 subjects of our study.
617
618   Figure 6: Decoding accuracy from different scalp regions of interest (ROIs). The box plots show
619   the r and the SNR values for the angular velocity and the joint angle calculated with electrodes
620   situated across 5 different scalp areas: left hemisphere (LH), right hemisphere (RH), anterior
621   (PF), centro-medial (SM), anterior-occipital (PO), and with all the electrodes (ALL). Both r-
622   values and the SNR values are shown. The scalp map depicts the coverage used for each ROI and
623   the location of the electrodes in each ROI. Right and left hemispheres have been separated by the
624   mid line. Mid-line electrodes (along the line linking FZ and OZ) have been included in neither the
625   right nor the left hemisphere ROIs.
626
627   Figure 7: Spatial distribution of r 2 decoding accuracies across sensors for the 'best' (S4) and
628   'worst' (S5) decoded subjects. Scalp maps represent the spatial distribution of 7'1 across
629   electrodes at the best lag for each parameter resulting from the training of the linear model. From
630   left to right, each column represents the scalp map of the Cartesian positions, joint angles and
631   angular velocities.
632
633   Figure 8: Decoding accuracy with the optimal number of sensors and the lowest number of
634   sensors. A) Mean (&std) Sensors Dropping Analysis (SDA) across the six subjects. B) Decoding
635   accuracy (r) obtained by using the best 34 sensors found by the SDA analysis (black) and by
636   using the highest r among the first best 16 sensors (white) for each subject. Each set of 2 bars
637   (black and white) represents the mean r -values (astd) for each subject. The last set of two bars
638   represents the grand average across the subjects for both the optimal condition (black) and the
639   plateau condition (white). C) Number of sensors used to compute the r -values when the 'best'
640   number of sensors was used (black) and up to 16 sensors were used (white) for each subject. Each
641   set of 2 bars (black and white) represents the r values (astd) of the six subjects.
23
EFTA00304390
642
643   Figure 9: Relationship between gait variability and decoding accuracy for the angular velocity
644   and joint position trajectories. A) Mean (tstd) of the kurtosis of the angular velocity across the
645   three joints (ankle, knee and hip); B) Mean (tstd) of the kurtosis of the joint angle across the
646   three joints (ankle, knee and hip); C) Box plots of the confidence intervals (70%) for the
647   bootstrapped r, kunosis paired values. The horizontal line represents the medians.
648
649
650
651
24
EFTA00304391
652   References
653
654   Acharya S, Fifer MS, Benz IlL, Crone NE, Thakor N. Electrocorticographic amplitude
655   predicts finger positions during slow grasping motions of the hand J Neural Eng 7 046002
656   doi: 10.1088/1741-2560/7/4/046002, 2010
657
658   Alkadhi H, Brugger P, Boendermarker SH, Crelier G, Curt A, Hepp-Reymond MC, Kollias
659   SS. What disconnection tells about motor imagery: evidence from paraplegic patients Cereb
660   Cortex 15: 131-140, 2005
661
662   Alpaydin E. Introduction to machine learning. Cambridge, MA:MIT, 2004, p. 254
663
664   Ball T, Schulze-Bonhage A, Aertsen A, Mehring C. Differential representation of arm
665   movement direction in relation to cortical anatomy and function J Neural Eng 6: 016006, 2009
666
667   Bakker M, de Lange FP, Stevens JA, Toni I Bloem BR. Motor imagery of gait: a quantitative
668   approach Exp Brain Res 179: 497-504, 2007
669
670   Bakker M, de Lange FP, Helmich RC, Scheeringa R, Bloem BR, Toni I. (2008) Cerebral
671   correlates of motor imagery of nonnal and precision gait Neuroimage 41: 998-1010, 2008
672
673   Behrman AL, Bowden MG, Nair PM. Neuroplasticity after spinal cord injury and training: an
674   emerging paradigm shift in rehabilitation and walking recovery Phys Ther 86: 1406-1425, 2006
675
676   Bradberry TJ, Contreras-Vidal JL, Rong F. Decoding hand and cursor kinematics from
677   magnetoencephalographic signals during tool use Conf Proe IEEE Eng Med Biol Soc; 5306:5309,
678   2008
679
25
EFTA00304392
680   Bradberry TJ, Rong F and Contreras-Vidal JL. Decoding center-out hand velocity from MEG
681   signals during visuomotor adaptation Netwoimage 47: 1691:1700, 2009a
682
683   Bradberry TJ, Gentili R, Contreras-Vidal JL. Decoding three dimensional hand kinematics
684   from electroencephalographic signals ConfProc IEEE EngMedBiol Soc; 5010:5013, 2009b
685
686   Bradberry T.I. Gentili R.I. Contreras-Vidal JL. Reconstructing Three-Dimensional Iland
687   Movements from Noninvasive Electroencephalographic Signals JNeurosci 30: 3432-3437, 2010
688
689   Bradberry TJ, Gentili RJ, Contreras-Vidal JL. Fast attainment of computer cursor control
690   with noninvasively acquired brain signals JNeural Eng 8(3):036010
691
692   Carmena M. Lebedev MA, Crist RE, O'Doherty JE, Santucci DM, Dimitrov DF, Patil PG,
693   licnriquez CS, Nicolelis MA. Learning to control a brain-machine interface for reaching and
694   grasping by primates PLoS BioL I, E42, 2003
695
696   Choi JT, Bastian AJ. Adaptation reveals independent control networks for human walking
697   Nature Neuroscience 10: 1055 - 1062, 2007
698
699   Christensen LO, Andersen JB, Sinkker T, Nielsen J. (2001) Transcranial magnetic stimulation
700   and stretch reflexes in the tibialis anterior muscle during human walking The Journal of
701   Physiology, 531: 545-557, 2001
702
703   Cramer SC, Lastra L, Lacourse MG, Cohen MJ. Brain motor system function after chronic.
704   complete spinal cord injury Brain 128: 2941-2950, 2005
705
706   Delorme A, Makeig S. EEGLAB: an open source toolbox for analysis of single-trial EEG
707   dynamics including independent component analysis JNeurosci Methods 134: 9-21, 2004
708
26
EFTA00304393
709   Dobkin BH, Firestine A, West M, Saremi K and Woods IL Ankle dorsiflexion as an fMRI
710   paradigm to assay motor control for walking during rehabilitation Neuroimage 32: 370-381, 2004
711
712   Fitzsimmons NA, Lebedev MA, Peikon ID. Nicolesis MA. Extracting kinematic parameters for
713   monkey bipedal walking from cortical neuronal ensemble activity Front. Integr Neurosci. 3:3.
714   doi:10.3389/neuro.07.003.2009, 2009
715
716   Goncharova II, McFarland DJ, Vaughan JR, Wolpaw JR. EMG contamination of EEG:
717   spectral and topographical characteristics CHI; Neurophysiol 114: 1580-1593, 2003
718
719   Gramann K, Gwin JT, Bigdely-Shamlo N, Ferris DP, Makeig S. Visual evoked responses
720   during standing and walking Frontiers in Human Neuroscience, 4:202, 2010
721
722   Grasso R, Ivanenko YP, Zago M, Molinari M, Scivoletto G, Castellano V, Macellari V,
723   Lacquaniti F. Distributed plasticity of locomotor pattern generators in spinal cord injured
724   patients Brain 127: 1019-1034, 2004
725
726   Grillner S, Wall€n P, Saitoh K, Kozlov A, Robertson B. Neural Bases of goal-directed
727   locomotion in vertebrates — An overview Brain Research Reviews 57: 2-12, 2008
728
729   Gwin JT, Grasman K, Makeig S, Ferris DP. Removal of movement artifact from high-density
730   EEG recorded during walking and running J Neurophysiol 103: 3526-3534, 2010a
731
732   Gwin JT, Grasman K, Makeig 5, Ferris DP. Electrocortical activity is coupled to gait cycle
733   phase during treadmill walking J Neuroimage 54(2): 1289-96, 2010b
734
735   Harada T, Miyai I. ,Kubota K. Gait capacity affects cortical activation patterns related to speed
736   control in the elderly Erp Brain Res 193: 445-454, 2009
27
EFTA00304394
737
738   Heuninckx S, Wenderoth N, Debaere F, Peeters R, Swinnen SP. Neural Basis of Aging: The
739   Penetration of Cognition into Action Control J of Neumsci, 25(29): 6787-6796, 2005
740   Heuninckx S, Wenderoth N, Swinnen SP. Systems Neuroplasticity in the Aging Brain:
741   Recruiting Additional Neural Resources for Successful Motor Performance in Elderly Persons J
742   of Neurosci, 28(1): 91-99, 2008
743
744   Iseki K, Hanakawa T, Shinozaki J, Nankaku M, Fukuyama H. Neural mechanisms involved
745   in mental imagery and observation of gait Neuroimage 41: 1021-1031, 2008
746
747   Jerbi K, Lachaux J P, N'Diaye K, Pantazis D, Leahy R M, Garnero L, Baillet S. Coherent
748   neural representation of hand speed in humans revealed by MEG imaging Proc Nall Acad Sci
749   USA 104: 7676-7681, 2007
750
751   Lachaux JP, Rodriguez E, Le Van Quyen M, Lutz A, Martinerie .1, Varela F.I. Studying
752   single-trials of phase synchronous activity in the brain J Bifurcation and Chaos 10(10): 2429-
753   2439, 2000
754
755   Lachaux JP, Lutz A, Rudrauf D, Cosmelli D, Le Van Quyen M, Martinerie J, Varela FJ.
756   Estimating the time-course of coherence between single-trial brain signals: an introduction to
757   wavelet coherence Clin Neurophysiol 32: 157-174, 2002
758
759   Luft A, Smith GV, Forrester L, Whitall G, Macko RF, Hauser TK, Goldberg AP, Hanley
760   DF Comparing brain activation associated with isolated upper and lower limb movement across
761   corresponding joints Human Brain Mapping 17: 131-140, 2002
762
763   Lunenburger L, Bolliger M, Czell D, Muller R, Dietz V. Modulation of locomotor activity in
764   complete spinal cord injury Exp Brain Res 174: 638-646, 2006
28
EFTA00304395
765
766   Lv J, Yuanqing L, Zhenghui G. Decoding hand movement velocity from electroencephalogram
767   signals during a drawing task Biomedical Engineering Online 9: 64 doi:10.1186/1475-925X-9-64,
768   2010
769
770   Nliyai I. 'Fa n a be 11C, Sase I, Eda H, Oda I, Konishi I, Tsunazawa Y, Suzuki T, Yanagida T,
771   Kubota IC. Cortical mapping of gait in humans: a near-infrared spectroscopy topography study
772   Neuroimage 14: 1186-1192, 2001
773
774   Nielsen JB. How we walk: central control of muscle activity during human walking
775   Neuroscientist 9: 195-204, 2003
776
777   Onton J, Delorme A, Makeig S. Frontal midline EEG dynamics during working memory
778   Neurolmage 27: 341-356, 2005
779
780   Pfurtscheller G, Brunner C, Schlogl, Lopes da Silva FH. Mu rhythm (de)synchronization and
781   EEG single-trial classification of different motor imagery tasks Neurolmage 31: 153-159, 2006
782
783   Rosslgnol S, Schwab M, Schwartz AB, Fehlings MG. Spinal cord injury: time to move? J.
784   Neurosc. 27: 11782-11792, 2007
785
786   Sahyoun C, Floyer-Lea A, Johansen-Berg H, Matthews PM. Towards an understanding of
787   gait control: brain activation during the anticipation, preparation and execution of foot
788   movements Neuroimage 21: 568-575, 2004
789
790   Suzuki M, Miyai I, Ono T, Oda I, Konishi I, Kochiyama T, Kubota K. Prefrontal and
791   premotor cortex are involved in adapting walking and running speed on the treadmill: an optical
792   imaging study Neuroimage 23: 1020-1026, 2004
29
EFTA00304396
793
794   Suzuki M, Miyai I, Ono T, Kubota K. Activities in the frontal cortex and gait performance are
795   modulated by preparation. An fNIRS study Nestroimage 39: 600-607, 2008
796
797   Tallon-Baudry C, Bertrand O, Delpuech C, Pernier J. Oscillatory y-Band (30-70 Hz) activity
798   induced by a visual search task in humans. J Neurosci 17(2): 722-734, 1997
799
800   Tononi G, Riedner BA, Hulse BK, Ferrarelli F, Sarasso S. Enhancing sleep slow waves with
801   natural stimuli. Medicamundi 54(2): 82-88, 2010
802
803   Tsuchiya N, Kawasaki H, Oya H, Howard MA 3rd, Adolphs IL Decoding face information in
804   time, frequency and space from direct intracranial recordings of the human brain PloS One 3(12):
805   e3892 doi: 10.1371/journal.pone.0003892, 2008
806
807   Van den Broek SP, Reinders F, Donderwinkel M, Peters ML Volume conduction effects in
808   EEG and MEG Electroenceph. Clin Nenrophysiol 64: 159-170, 1998
809
810   Walden S, Preissl H, Demandt E, Braun C, Birbaumer N, Aertsen E, Mehring C. Hand
811   movement direction decoded from MEG and EEG J Nenrosei 28: 1000-1008, 2008
812
813   Wieser M, Haefeli J, Butler L, Jancke L, Riener R, Koeneke S. Temporal and spatial patterns
814   of cortical activation during assisted lower limb movement Exp Brain Res 203: 181-191, 2010
815
816   Zhuang J, Truccolo W, Vargas-Irwin C, Donoghue JP. Decoding 3-D reach and grasp
817   kinematics from high-frequency local field potentials in primate primary motor cortex.
818   IEEE Trans Monied Eng 57(7):1774-84, 2010
30
EFTA00304397
C 3D Kinematic
Footswitches
(and -Pass Alter
(   Optimized
Decoder
EFTA00304398
A         40
35
El 30
1p
.43   20
E
2 15
5
2         3     4    5
Frequency (Hz)
B         50
40
171* 30
-o
O 20
a.
10
0
10       15     20   25
Frequency (Hz)
EFTA00304399
A                  Ankle                Knee                    Hip
X (m)      ()." ‘MAik              k /14P44C SN't‘
-0.06
0.1m          m
Y(m)
0.1
2 (m)                              •./NheNP-Nr4—%
Angle (1
-60 e‘‘Itst'llselAr‘P
3501
Ang Vel
(°/sec)
-300
1      4        8    1      4         8    1        4       8
Time (sec)
B                  Ankle               Knee                       Hip
0.1
X (m)
0.4
Y (m)
-0.4
0.15
(m)
-0.08
Angle (1
1            01
Ang Vel
(°/sec)
1       4         8       1        4       8
Time (sec)
EFTA00304400
Ang Vel
A
0.
x
0
Knee                .2
-2 4             Ankle
— Predicted
B        2
Joint Angle
— Actual
.1
Knee    -4    4
Ankle
EFTA00304401
Decoding Accuracy (r)
0      0     0
4:.    en    co                     _1,
*•
•   * **
.
.
_.x
. •
0              g g cn cn cn cn Cl) u)
N                   —.
-& cm ui -P. W n.)
EFTA00304402
Ang Vel                                                   Joint Angle
0.9                                                          0.9
•
0.8
o
0.8-
a)
co                                                                               E
L            0.7                                                          0.7.
0.6                                                          0.6.
LH       RH   PF    SM         PO    ALL                     LH    RH     PF     SM   PO   ALL
7                                                             7
SNR values
5     -
3                                                             3
El
1                                                             1
LH       RH   PF    SM         PO    ALL                     LH    RH     PF     SM   PO   ALL
Brain Regions
LH                                               RH
•AF3                  •AF4
„     • F8
PF        F7         •FA
•• -   •F3 •F1          Fz •F2 •F4 '"
•FC5 .Fc3 •FC1 FCz •FC2 •FC4 •FC
•C5 .C3             •C1       Cz    •C2        .C4    •C6
SM
•CP3 •CP1 CPz •CP2 •CP4
.p5
.P3 •P1      PZ •P2 .p4 p6
PO1    PO2
PO                               PO3      ••z       PO4
2
EFTA00304403
0.21    0.12
0       0
0.23   113
0       0
0.12   10.24
0
0.06   1.07
0       0
0.08
a)
as
C
Y
0       0
10.03
1
.26   a   0.16
0         0       0
EFTA00304404
0.9
0.8
3 0.7
A        !OS
0.6
0.4
0        5        10   15      20    25        30   35
Number of sensors
1
B
U
U
0.6
< 0.4
a)
C
0
N
0.2
o
40
S1       S2      S3    S4
■ Optimal sensors
a Plateau sensors
ril
S5       S6    Mean
Number of sensors
C
S1       S2      S3    S4    S5       S6    Mean
EFTA00304405
Kurtosis (Ang Vel)
4
3
A
2
1
0L
81        S2      S3   S4      S5    S6
14
Kurtosis (Joint Angle)
12
10
8
B
6
4
2
0                                I
S1     S2      S3   S4      S5    S6
Correlation Coefficient (r)
0.6
0.4
0.2
C                                   0
-0.2
-0.4
-0.6
Ang Vel             Joint Angle
EFTA00304406
Table I : Comparison of decoding results in nonhuman primates with the current human study.
Spikes                                                                 EEG
Monkey 1                          Subject 4 (Best)            Subject 6 (Worst)              Mean (6 subjects)
Ankle               r          SNR              r            SNR             r             SNR           r            SNR
X           0.79 10.09    4.08 11.8      0.8110.02      4.7110.67     0.59 10.12     14311.74      0.6810.17      1.9 ± 1.74
Y           026 ± 0.11    626±2.66       0.92 ± 0.009   8.13 1048     0.71±0.17      2.64 13.34    0.8 ± 0.08    424 12.11
Z           0.44 ± 0.16   -0211.48       0.92 ± 0.009   8.0310.4      0.7310.11      3.0412.38     0.76 t 0.1    4.2712.19
Joint Angle          NIA          N/A        0.87±0.01      6.1 t 0.69    0.68 10.11     2.19 ± 2.44   0.68±0.08     2.81 t 1.16
Ang WI              NIA          NIA        0.81 ± 0.03    4.54 ± 01     0.67±0.08      2.11±2.04     0.71 t 0.08   326 ± 1.63
Knee                r          SNR              r            SNR             r             SNR           r            SNR
X           026 10.14     1.96±1.84       0.610.06      1.910.66      0.410.07       0.1610.87     0.6710.16     222 t 1.43
Y           0.79 ± 0.13   4.28 t 2.02     0910.01       721±0.6       0.71±0.14      2.64 t 2.61   0.82 t 0.07   6.11 t 1.98
Z           0.39±0.13     .0.62 ± 1.36   02110.006      7.71±0.61     0.74 10.08     3.12 ± 1.92   0.8±0.07       4.73 t 1.8
Joint Angle     024 ± 0.07    6.29±2.06      0.92 ± 0.01    8.41 ± 0.6    0.76 ± 0.1     329 122       0.85 ± 0.04   6.96 ± 1.36
Ang WI              NIA          NIA         0910.02       7.16 10.86    0.8110.08      4.62122       0.84 ± 0.05   6.76 t 1.66
Hip                r          SNR              r            SNR             r             SNR           r            SNR
X           0.610.14      1.16±1.71      0.7610.04      3.6810.68     0.5710.08      1.05115       0.7710.11     3.6411.47
Y           0.66 10.14    1.97 ± 1.92    0.8210.01      4.86 10.31    0.72 ± 0.07    2.84 ± 1.77    0.7±0.1      2.97 ± 1.44
Z           0.6610.13     0.66 11.76     0.8610.02      6.810.72      0.71I 0.1      2.911.99      0.81±0.06       6 ± 1.43
Joint Angle     0.73 ± 0.11   2.96 ± 1.96     0.9 ± 0.01    729 ± 0.6     0.68 t 0.16    2.11±3.16     0.81 ± 0.07   6.03 ± 1.79
Ang WI              NIA          N/A        0.88 1 0.006   6.56 1 0.31   0.7110.13      2.77125       0.8±0.09       4.82 ± 2.3
Correlation coefficient (r) and SNR (dB) for the prediction of different walking parameters for
Monkey 1 (Fitzsimmons et al. (2009)), the best (S4) and worst (S5) decoded subjects, and for the
mean across the 6 subjects in the current study. The numbers represent mean ± standard
deviation.
EFTA00304407
Table 2: Comparison of decoding results between precision and natural walking.
Subject 4 (Precision           Subject 4 (Natural        Subjed 5 (Precision walking)       Subject 5 (Natural
walking)                      walk ng)                                                     walking)
Ankle            r            SNR              r           SNR               r            SNR              r           SNR
X        0.01 ± 0.02    4.71 2 0.67    0.47 I 0.17   .1.55 I 4.51    0.59 ± 0.12    1.43: 1.74     0.77:0.03     3.81 I 0.65
Y         0.92 ± 0.009   8.13 I 0.48    0.75 I 0.16   326 t 3.45      031:0.17       2.61 ± 3.34    0.83 ± 0.03   4.99 : 0.84
Z         0.92: 0.009    8.03:0.4       0.01 * 0.11   4.58* 2.99      0.73 * 0.11    3.04 * 2.38    096:0.02      5.69:0.55
Joint Angle   0.87 I 0.01    6.1I 0.59      0.68 2 0.13    1.79 ± 3       0.68 i 0.11    2.19 I 2.44    0.81: 0.02    5.43 : 0.64
Ang Vel      021 1 0.03     4.54 ± 0.7     0.75 1 0.07   3.52 2 1.43     0.67: 0.08     2.11 2 2.04    0.82:0.02     4.74 ± 0.68
Knee            r            SNR              r           SNR               r            SNR              r           SNR
X         0.6 I 0.06    1.9 2 0.66     0.37 I 0.11   .1.03 I 3.02    0.4 t 0.07     0.15 I 0.87    0.36 ± 0.04   0.81 s 0.62
Y          0.9 ± 0.01    7211 0.6       0.74 a 0.07   2.45 i 222      0.71 I 0.14    2.61 i 2.61    022 * 0.04    4.97 : 1.07
Z         0.91 i 0.005   7.71 :0.51     0.76 a 0.09   3.49 t 2.44     0.74:0.08      3.12: 1.92     0.85:0.02     5.63:0.76
Joint Angle   0.92 ± 0.01    8.411 0.6      022 s 0.1     4.82 ± 2.82     0.75:0.1        329 s 22      096:0.02      593:099
Ang Vel       09: 0.02      716 1 0.86     024 1 021     523 s 1.42      0.81 ± 0.0B     4.62 s 22     0.87:0.02     6.22: 0.71
Nip             I            SNR              r           SNR               r            SNR              r           SNR
X        0.76 a 0.04    3.68 a 0.68    0.64 a 0.15   0.79:3.54       0.57:0.08       1.05:15       0.67:0.03     238:0.39
Y         0.82 a 0.01    4.86 a 0.31    0.71 a 0.19   2.3 I 4.05      0.72 t 0.07    2.84 I 1.77    0.79 1 022    4.17 ± 0.61
Z         0.85 1 0.02    5.8 1 0.72     0.01 1 0.09   4.64 2 2A2      0.71 ± 0.1      2.9 ± 129     023 ± 0.03     5.1:0.79
Joint Angle    0.9 2 0.01    7.29 2 0.6     022 2 0.07    4.72 t 1.93     0.60 2 0.16    2.11 2 3.16    0.81 ± 021    4.71 2 1.04
Arig Vel     0.88 ± 0.006   6.56 2. 0.31   0.66 I 0.14   1.27 t 3.02     0.71 ± 0.13     2.77:25       0.81 ± 0.03   4.74 s 0.72
Correlation coefficient (r) and SNR (dB) for the prediction of different walking parameters for the
best (S4) and worst (S5) decoded subjects under precision and natural walking. The numbers
represent mean f standard deviation.
EFTA00304408
Table 3: Comparison of decoding accuracy (r) and weights between decoding with and without
eye- electrode.
Subject 1          Subject 2           Subject 3           Subject 4           Subject 5             Subject 6
Ankle       %weight         %r   %weight   %r       %weight        %r   %weight    %r       %weight        %r    %weight         %r
X            0.1          0      0.1     2.9       AM        .1.4      0.08          0     0.07      3.5        0.05       3.1
Y            0.03     -12       0.05     5.1       0.07      -1.1      0.09          0     0.06      2.8        0.07       -1.1
Z            0.05         0     28.7     9.6       0.18          0     005           0     0.06          1.3    0.06           0
Joint Angle      0.1          0     0.09         0     024           0     0.12      -121      0.03      -14        0.06           0
Ang Vel         0.04         0     0.09     4.4       0.09          0      0.1      -1.1      0.04          0      0.12           0
Knee       %weight     iii      %weight   in       %weight    in       %weight    in       %weight        %r    %weight         %r
X            0.07         0     0.14     -12       0.12      -135      008       -1.6      0.05          0      0.06       1.75
Y            0.07         0     0.11         .6    007           -1    004           -1    0.04      2.8        004            0
2            0.06         0     0.13     2.3       0.06      .13       0.09          0     0.03          1.3    0.06           0
Joint Angle      0.04     12        0.08     4.1       0.04      4.1       0.09          0     0.01          0      0.02           0
Mg WI           0.1          0     0.13     22        0.08      -1.1      0.11          -1    007       135        003            0
Hip        %weight         %r   %weight   %r       %weight        %r   %weight    %r       %weight        %r    %weight         %r
X            005      -12       0.13     aO        0.08          0     0.04      -12       006       1.78       004            0
Y            005      -1.4       0.1         0     0.01      .1.23     0.09          0     005           0      0.12       .1.88
Z            007      42        0.11         0     0.01          0     0.01      22        OAS           1.4    0.05           0
Joint Angle      005          0     0.07     -4.7      OM            0     0.01      -1.1      022           1.4    004            0
Mg Val          0.06         0     0.09     -73       0.06          -1    0.06          0     0.05          3      0.04           0
The difference in °A., between correlation coefficient (r) and the ratio between weights for the
prediction of different walking parameters for the six subjects decoded under precision walking
with and without eye-electrode are shown in table 3. Positive values mean an increase of r and
weight with eye-electrode, while negative values mean a decrease of r and weight with eye-
electrode.
EFTA00304409
← EFTA00304364Dataset 9EFTA00304410 →